Guangzhou Benray Medical Equipment Co., Ltd.

Guangzhou Benray Medical Equipment Co., Ltd. Advanced Machines & Technology Strict Quality Control Innovative R&D Power Professional Service

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Patient Monitor /

12″ Patient Monitor

Product Categories
Contact Now
Guangzhou Benray Medical Equipment Co., Ltd.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MrKelvin Chen
Contact Now

12″ Patient Monitor

Ask Latest Price
Video Channel
Contact Now

Add to Cart

Find Similar Videos
View Product Description
12″ Patient Monitor

BR-PM14

12.1" color TFT screen
Multi‐channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms



Alarm review, arrhythmia review
Patient info. Input
Anti‐defibrillation design
NIBP over pressure protection
Plug‐in rechargeable battery, AC/DC available.
Supporting wire or wireless network.


Technical Specifications

ECG

Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V
Wavef orm 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Wave form 1 ch
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ±1% or±1bpm, which is greater
Resolution 1 bpm
Sensitivity > 200 (uVp-p)
Differential Input Impedance > 5 MΩ

CMRR Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range ±8 m V ( Vp-p )

Bandwidth Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Calibration Signal 1 (mVp-p), Accuracy:5%
ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
PNP, PNC,Alarm Available,Review Available


Respiration

Method Impedance between R-F(RA-LL)
Differential Input Impedance > 2.5 MΩ
Measuring Impedance Range 0.3~3 Ω
Base line Impedance Range 200~4 KΩ
Bandwidth 0.1~2.5Hz
Resp. Rate Measuring and Alarm Range
Adult 0 ~ 120 Brpm
Neo/Ped 0 ~ 150 Brpm
Resolution 1 Brpm
Accuracy ±2 Brpm

Apnea Alarm 10 ~ 40 S





NIBP

Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN

Measuring and alarm range Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution 1mmHg

Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg

SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate Measuring and Alarm Range 20~300 bpm
Resolution 1bpm
Accuracy ±3bpm



TEMP

Channel 2
Measuring and Alarm Range0 ~ 50 ℃
Resolution 0.1 ℃
Accuracy ±0.2 ℃
Actualization intervalabout 1 Sec.
Average Time Constant < 10 Sec.


IBP

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP-10 ~ 40 mmHg
P1 / P2-10 ~ 300 mmHg


Press Sensor Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω

Resolution 1 mmHg
Accuracy ±2% or 1mmHg which is greater
Actualization interval about 1 secretary


Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: Nellcor SpO2, EtCO2, IBP,TEMP-2, Thermal Recorder,Wall Mount,Trolly,Central station























































































































































Inquiry Cart 0